https://www.avient.com/resources/safety-data-sheets?page=1496
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=1298
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=5679
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=6598
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=4199
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=6362
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=6273
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/sites/default/files/2024-03/Edgetek PKE High Impact Formulations Technical Bulletin.pdf
TECHNICAL
PROPERTIES(1) TEST METHOD
Edgetek™
ET8900-0011
HI UV NAT
Edgetek™
ET8900-0012
HI UV White
Edgetek™
ET8900-0013
HI UV Black
Physical
Density/Specific Gravity ASTM D792 1.13 g/cm3 1.15 g/cm3 1.13 g/cm3
Molding Shrinkage - Flow ASTM D955 1.4–2% 1.4–2% 1.4–2%
Mechanical
Tensile Strength (Yield) ASTM D638 5,900 psi 5,800 psi 5,800 psi
Tensile Modulus(2) ASTM D638 169,000 psi 161,087 psi 176,000 psi
Flexural Modulus(3) ASTM D790 187,000 psi 190,985 psi 188,000 psi
Impact
Notched Izod Impact
73°F (23°C), 0.125 in ASTM D256A 17.3 ft-lb/in 16.5 ft-lb/in 16.5 ft-lb/in
Notched Izod Impact
-22°F (-30°C), 0.125 in ASTM D256A 3.2 ft-lb/in 3.0 ft-lb/in 3.3 ft-lb/in
Thermal (HDT)
66 psi (0.45 MPa), 0.125 in ASTM D648 121°C 135°C 129°C
NORTH AMERICA GRADES
(1) Data based on single lot of lab generated samples.
https://www.avient.com/sites/default/files/2023-09/Cesa Fiber Additives for Heat Preservation Technical Bulletin.pdf
TEMPERATURE DISTRIBUTION DIAGRAM
• Test Method: FTTS-FA-010-2007 4.2
• Equipment: Thermovision
• Heat Source: 500W Halogen Lamp
• Heat Distance: 100 cm
Surface temperature before exposure: 20.22°C
Surface temperature after 10 min exposure: 33.85°C
Temperature change: +13.6°C
Added Cesa Fiber Additives for heat preservation
TEST METHOD STANDARD REQUEST TEST RESULT
GB/T30127
Far infrared radiation properties
Far infrared emissivity ≥0.88 (5-14um)
(Test temperature: 34°C) 0.9
Far infrared radiation
temperature rise ≥ 1.4°C 9°C
GB/T 18319-2019
Thermal retention with accumulated
by infrared ray
Maximum temperature rise ≥ 6°C 8.9°C
Mean temperature rise ≥ 4.4°C
(20 minutes) 5.6°C
FTTS-FA-010
Infrared radiation properties &
thermal retention temperature rise
Average emissivity ≥ 0.8 (2-22um)
(Test temperature: 25°C) 0.8
Specified heating ΔT ≥ 0.5°C
(relative to the standard) +5.34°C (ΔT)
GB/T 11048-2008 Method A
Thermal transmittance
Unit: clo
Naked body: 0
Underwear: 0.04
T-shirt: 0.09
Thick sweater: 0.35
Winter coat: 0.7
All the data above are the reference value
0.625
Human Physiological Experiment
Blood flow volume +12.9%
Blood flow velocity +13.6%
Blood oxygenation(%SpO2) +1.7%
www.avient.com
Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2023-11/Capture Oxygen Scavenger Product Bulletin.pdf
Data shows
Capture does not affect the polyolefin stream even
when it consists of 100% Capture closures.