https://www.avient.com/sites/default/files/2025-03/ColorMatrix SmartHeat RHC Brochure.pdf
IMPROVED BOTTLE
QUALITY
+2% in
neck
+3% in
body
-12% in
base
8.5g 0.5L bottle, 60% rPET
Polymer Weight Distribution
Based on commercially produced water
bottles, 51,000bph
Mechanical Strength
Based on PTI 14.4g 0.5L water bottles, Instron testing
To
p
Lo
ad
(l
bs
)
Burst Pressure
Based on 8.5g, 0.5L commercially produced water bottles
Bu
rs
t P
re
ss
ur
e
(B
ar
)
REDUCED CO2 EMISSIONS
Based on a commercial process producing 8.5g 0.5L water bottles as 51,000bph
25% reduction in energy consumed during the bottle blowing process
En
er
gy
k
W
Reduce Energy Consumption
SmartHeat RHC increases the heat-up rate for preforms, enabling energy reductions
for the heating lamps used during the bottle blowing process.
Melt processing of SmartHeat RHC
products is carried out at typical PET
processing conditions at recommended
dose rates, which range from .02%
to .075%.
Care must be taken to optimize the bottle
blowing process due to the increased
heat-up rate of the preform, to take
advantage of the many benefits offered
by this product range.
https://www.avient.com/sites/default/files/2020-12/firecon-cpe-product-bulletin.pdf
Cable constructions using FireCon CPE formulations
are suitable for the following UL Standards:
UL 13 - Power-Limited Circuit Cables
UL 44 - Thermoset-Insulated Wire and Cable
UL 62 - Flexible Cords and Cables
UL 1277 - Electrical Power and Control Tray
Cables with Optional Optical-Fiber
Members
UL 2250 - Instrumentation Tray Cable
KEY CHARACTERISTICS
• Retains flexibility at temperatures below 0°C
• Resistant to acids, alkalis, oils, fuels and
chemical solvents
• Excellent balance of physical properties
• Suitable for VW1 and tray cable rated
applications
• Available in UV resistant grades
• Available in custom colors
MARKETS AND APPLICATIONS
• Oil, gas and petroleum applications
• Tray cable
• Industrial cable
• Low-voltage power cables
• Medium-voltage power cables
• Control cables
• VW1 applications
PRODUCT BULLETIN
To learn more about FireCon CPE jacketing solutions,
contact Avient at 1.844.4AVIENT
www.avient.com
FIRECON™ CPE 30-33 RoHS
CPE 37-36 RoHS
CPE 37-31 RoHS
CPE 37-31 RoHS
Natural
Specific Gravity 1.31 1.38 1.39 1.39
MFI (190°C, 21.6 Kg) 15 22.4 34.3 34
Durometer Hardness 39D 31D 34D 34D
Tensile Strength, PSI 1,499 2,200 2,096 1,800
Tensile Elongation (%) 350 300 325 300
UL Temperature Rating °C 90 90 90 90
LOI (% Oxygen) 30 37 37 37
Brittleness Temperature °C -33 -36 -31 -31
TECHNICAL PROPERTIES
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/2021-04/versaflex-tpe-contact-lens-case-case-study.pdf
This not
only caused a high scrap rate, but also led to frequent
interruptions in the automated process so that the mold
and machine could be cleaned.
In addition to a lower material cost
than silicone, the Avient solution offered cycle time
efficiencies, lower part weight due to its lower specific
gravity, and reduced scrap rates.
https://www.avient.com/sites/default/files/2021-04/versalloy-medical-tubing-case-study.pdf
In addition to its excellent colorability and high flow,
the Versalloy solution possessed a lower specific gravity
and resulted in lower scrap rates compared to the
competitive TPV, providing the opportunity to reduce
system costs.
These savings resulted from lower specific
gravity of the Avient material (0.88 compared to 0.95)
and a 50% reduction in scrap rate.
https://www.avient.com/sites/default/files/2020-10/fluoropolymer-cable-case-study-.pdf
The manufacturer’s cable lines, in turn, saw a higher
scrap rate, which led to delayed deliveries to customers
and eventually to the need for price hikes.
On its manufacturing lines, the transition to Colorant
Chromatics fluoropolymer color concentrates helped
slash its scrap rate from 10% to less than 5%.
https://www.avient.com/sites/default/files/2024-11/Ballistic Panel Infographic.pdf
UL Rating Ammunition Velocity No.
Characteristic
GlasArmor
Thermoset
Panels
ThermoBallistic
Thermoplastic
Panels
Steel Concrete
Performance-to-Weight
Bullet Resistance – Pistols
Bullet Resistance – Rifles NA1
Temperature Performance 2
UV Resistance 3
Electrical Conductivity
Flame Retardance 5 4
Ease of Installation
1 Ballistic resistance to rifle fire can be achieved by layering
ThermoBallistic and GlasArmor panels – contact Avient
2 ThermoBallistic panels made with polypropylene resin systems
3 UV resistance is achieved using surface polymeric films
4 Flame retardant additives can be incorporated upon request under
some circumstances
5 Fire rated for 1-hour per ASTM E-119-09c when tested in an interior
wall system
Compare
the
different
materials
used for
ballistic
protection
https://go.avient.com/BallisticProtection?
https://www.avient.com/sites/default/files/2024-01/Global Standard Response_Dec 2023.pdf
While we believe
the information contained in this document should be responsive to most inquiries, if you
have questions not answered by this document you should reach out to your sales
representative, who is your primary contact, and can forward your request to an appropriate
person.
All persons attending the audit may be required to sign an individual non-
disclosure agreement prior to being permitted into Avient facilities.
Additionally,
personal protective equipment may be required in certain areas of the facility
https://www.avient.com/sites/default/files/resources/TRA%2520-%25202016%2520Annual%2520Report%2520for%252015%2520Tideman.pdf
Business Number: 898451794
Mailing Address: Delivery Mode: GeneralDelivery
Address Line 1: 17 Tideman Drive
City, Province/Territory, Postal Code: Orangeville Ontario L9W3K3
Country: Canada
Facility Name: Orangeville Plasticizer
NAICS Code: 326198
NPRI ID: 2277
Physical Address: Address Line 1: 15 Tideman Drive
City, Province/Territory, Postal Code: Orangeville Ontario L9W3K3
Country: Canada
Latitude: 43.9133
Longitude: 80.1158
Contact Type Technical Contact, Company Coordinator, Public Contact, Person who coordinated the
preparation of the Toxics Reduction Plan
Name: Brian Greer
Position: EHS Manager
Telephone: 5192150535
Email: brian.greer@polyone.com
Contact Type Certifying Official
Name: Darryl Chartrand
Position: Senior Air Quality Technologist
Telephone: 4164999000
about:/V003/Html
http://www.canada.gc.ca/home.html
http://www.servicecanada.gc.ca/eng/home.shtml
http://www.canada.gc.ca/aboutgov-ausujetgouv/depts/menu-eng.html
https://ec.ss.ec.gc.ca/auth/en/Services
about:/V003/Logout_Deconnexion
http://ec.gc.ca/default.asp?
lang=En&n=FD9B0E51-1
https://ec.ss.ec.gc.ca/auth/en/Services
General Information
Substance List
CAS RN Substance Name Releases Releases (Speciated VOCs) Disposals Recycling Unit
103231 Bis(2ethylhexyl) adipate 0.0000 N/A N/A N/A tonnes
117817 Bis(2ethylhexyl) phthalate 0.0001 N/A N/A N/A tonnes
85449 Phthalic anhydride N/A N/A N/A N/A tonnes
Extension 73642
Fax: 4164994687
Email: darryl.chartrand@ch2m.com
Contact Type Highest Ranking Employee
Name: Robert Greenop
Position: Plant Manager
Telephone: 5199385865
Email: robert.greenop@polyone.com
Mailing Address: Address Line 1:
City, Province/Territory, Postal Code: None
Country: None
Contact Type Person who prepared the report
Name: Najat Kamal
Position: EHSQ specialist
Telephone: 5148089920
Email: najat.kamal@polyone.com
Mailing Address: Delivery Mode: GeneralDelivery
Address Line 1:
City, Province/Territory, Postal Code: None
Country: None
Number of employees: 16
Activities for Which the 20,000Hour Employee
Threshold Does Not Apply:
None of the above
Activities Relevant to Reporting Dioxins,
Furans and Hexacholorobenzene:
None of the above
Activities Relevant to Reporting of Polycyclic
Aromatic Hydrocarbons (PAHs):
Wood preservation using creosote: No
Is this the first time the facility is reporting to
the NPRI (under current or past ownership):
Is the facility controlled by another Canadian
company or companies:
Did the facility report under other
environmental regulations or permits:
Is the facility required to report one or more
NPRI Part 4 substances (Criteria Air
Contaminants):
Operating Schedule Days of the Week: Mon, Tue, Wed, Thu, Fri
Usual Number of Operating Hours per day: 24
Usual Daily Start Time (24h) (hh:mm): 07:00
CAS RN Substance Name Releases Releases (Speciated VOCs) Disposals Recycling Unit
Applicable Programs
CAS RN Substance Name NPRI ON MOE TRA ON MOE Reg 127/01
First report for
this substance to
the ON MOE TRA
103231 Bis(2ethylhexyl) adipate Yes Yes Yes
117817 Bis(2ethylhexyl) phthalate Yes Yes No
85449 Phthalic anhydride Yes Yes No
General Information about the Substance Releases and Transfers of the Substance
Was the substance
released onsite
The substance will be reported as the sum of releases
to all media (total of 1 tonne or less)
1 tonne or more of a Part 5 Substance
(Speciated VOC) was released to air
Yes Yes No
Yes Yes No
General Information about the Substance Disposals and Offsite Transfers for Recycling
Was the substance disposed of (onsite or off
site), or transferred for treatment prior to final
disposal
Is the facility required to report on disposals of
tailings and waste rock for the selected reporting
Was the substance
transferred offsite for
recycling
General Information about the Substance Nature of Activities
CAS RN Substance Name Manufacture the Substance Process the Substance Otherwise Use of the Substance
103231 Bis(2ethylhexyl) adipate For sale/distribution As a formulation component As a byproduct
117817 Bis(2ethylhexyl) phthalate For sale/distribution As a formulation component As a byproduct
85449 Phthalic anhydride As a byproduct As a reactant As a byproduct
TRA Quantifications
CAS RN Substance Name Use, Creation, Contained in Product Quantity Use ranges for public reporting
103231 Bis(2ethylhexyl) adipate Use 0.000 tonnes Yes
103231 Bis(2ethylhexyl) adipate Creation 27.159 tonnes Yes
103231 Bis(2ethylhexyl) adipate Contained in Product 27.159 tonnes Yes
117817 Bis(2ethylhexyl) phthalate Use 0.000 tonnes Yes
117817 Bis(2ethylhexyl) phthalate Creation 0.104 tonnes Yes
117817 Bis(2ethylhexyl) phthalate Contained in Product 0.104 tonnes Yes
85449 Phthalic anhydride Use 4228.7 tonnes Yes
85449 Phthalic anhydride Creation 0.000 tonnes Yes
85449 Phthalic anhydride Contained in Product 4228.7 tonnes Yes
TRA Quantifications Others
Change in Method
of Quantification
Reasons
for
Description of how the change impact
tracking and quantification of the substance
Description of how an
incident(s) affected
quantifications
Significant
Process
Change in Method
of Quantification
Reasons
for
Description of how the change impact
tracking and quantification of the substance
Description of how an
incident(s) affected
quantifications
Significant
Process
Total Quantity Released (All Media)
CAS RN Substance Name Category Basis of Estimate Detail Code Quantity
103231 Bis(2ethylhexyl) adipate Total Quantity Released O Engineering Estimates 0.0000 tonnes
117817 Bis(2ethylhexyl) phthalate Total Quantity Released O Engineering Estimates 0.0001 tonnes
Onsite Releases Quarterly Breakdown of Annual Releases
CAS RN Substance Name Quarter 1 Quarter 2 Quarter 3 Quarter 4
117817 Bis(2ethylhexyl) phthalate 25 25 25 25
Onsite Releases Reasons for Changes in Quantities Released from Previous Year
CAS RN Substance Name Reasons for Changes in Quantities from Previous Year Comments
117817 Bis(2ethylhexyl) phthalate No significant change (i.e.
Note: Only the person identified as the Certifying Official or the authorized delegate should submit the report(s) identified below.
https://www.avient.com/sites/default/files/2024-03/QF-02 QMS Global Standard Response.PDF
While we believe
the information contained in this document should be responsive to most inquiries, if you
have questions not answered by this document you should reach out to your sales
representative, who is your primary contact, and can forward your request to an appropriate
person.
All persons attending the audit may be required to sign an individual non-
disclosure agreement prior to being permitted into Avient facilities.
Additionally,
personal protective equipment may be required in certain areas of the facility
https://www.avient.com/sites/default/files/2022-08/Humotech Robotic Prosthetic Case Study.pdf
ROBOTIC EMULATION
ENABLES PERSONALIZED
PROSTHETICS WITH
COMPOSITES
Photo courtesy of the DoD Center for the Intrepid
COMPOSITE SPRINGS PROVIDE FLEXIBILITY IN PROSTHETIC
PERFORMANCE AND DESIGN
© 2022, All Rights Reserved
Avient Corporation, 33587 Walker Road, Avon Lake, Ohio USA 44012
To learn more, please contact Avient at
1.844.4AVIENT (1.844.428.4368) or visit
www.avient.com.