https://www.avient.com/news/archives?page=42
CLEVELAND – December 11, 2018 – PolyOne today announced an agreement with Cooper-Standard Holdings Inc. to license its high-performance
December 11, 2018
https://www.avient.com/investors/investor-news?page=11
11
Jul 11, 2019
https://www.avient.com/investors/investor-news?page=15
11
Jan 11, 2018
https://www.avient.com/news/archives?page=14
Avient and Virginia Tech Collaborate: Industrial Design Students Challenged in Automotive Aftermarket Part Competition on October 11, 2023.
October 11, 2023
https://www.avient.com/investors/investor-news?page=13
11
Oct 11, 2018
https://www.avient.com/investors/investor-news?page=4
11
Oct 11, 2022
https://www.avient.com/sites/default/files/2023-08/QRG for suppliers on CSP order management%5B87%5D.pdf
In the Create Shipment
Tracker popup window, enter the tracking number for the entire PO, select a carrier (FedEx,
USPS, UPS) from the drop-down window, and add a note (optional).
https://www.avient.com/sites/default/files/2020-08/colormatrix-joule-tech-bulletin-a4.pdf
CAUSE AND EFFECT DIAGRAM
Methods Machines
Materials Manpower
energy
saving
during
SBM
Maintenance
instructions
Operating
instructions
Operator
Job spec
NIR Lamps
SBM
Type/Design
vPET reheat
content
vPET
formulation
rPET
blend/quality
Temperature
recording
Temperature
measurement
probe
External
temperature
Inappropriate
Manual
Training
New
Alignment
Same
Throughput
Too many tasks
Time conflict
Age/intensity
variable
Set up conditions
Configuration
- When starting to process a new resin, first
run through new preforms for 15 minutes at
‘standard’ conditions to establish steady state
conditions prior to any process optimization
- Slowly start to reduce preform blowing
temperatures until failures are present
(visible pearl internal wall or pearl feet)
- Increase blowing temperatures until defects
are eliminated
- QC check bottle quality for acceptance versus
established tolerances
- Change the power consumption profile in the
ovens for early heat and longer sink times but
ensure overall temperatures do not exceed cold
crystallization temperature
- Repeat temperature reduction stage and
then defect elimination stage to test if further
optimization is possible
- Recheck QC bottle quality for acceptance versus
established tolerances
- Log all process parameters and create new
specific ‘recipe’ for future use
www.avient.com
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/2020-08/colormatrix-flexcart-micro-liquid-metering-system-flyer.pdf
ATTRIBUTE PC
PUMP
PERI
PUMP
CMG
3000
CMG
5000
Metering throughput High Low – –
Volumetric/gravimetric V V V V/G
Data export/network – – No Yes
Touch screen – – No Yes
Multiple log-in levels – – No Yes
The range of progressing
cavity pump rates attainable
can be usedto determine
the correct size of pump.
https://www.avient.com/sites/default/files/2021-09/colormatrix-flexcart-liquid-metering-system-flyer.pdf
ATTRIBUTE PC PUMP PERI PUMP CMG3000 FLEX G CMG5000 CMG6000
Delivery throughput High Low – – – –
Metering throughput High Low – – – –
Volumetric/gravimetric V V V Loss-in-weight G G
Data export/network – – No Yes Yes Yes
Touch screen – – No Yes Yes Yes
Multiple log-in levels – – No No Yes Yes
The range of progressing
cavity pump rates
attainable can be used to
determine the correct size
of pump.