https://www.avient.com/sites/default/files/2023-05/Cesa Stat Product Selector Guide.pdf
Most temporary antistatic additives
require time to reach maximum effectiveness,
typically 2 to 7 days.
https://www.avient.com/sites/default/files/2023-06/Cesa_ Stat Antistatic Additives for Automotive - Application Bulletin.pdf
Cesa Stat Antistatic Additives for automotive can
support customers with electrostatic decay time
testing according to Standard DIN EN 61340-2-1
to speed up the development.
https://www.avient.com/sites/default/files/2023-08/EVSE Industry Bulletin.pdf
Electric Vehicle (EV) Charging Market
Solutions for Level 1, 2, and DC public charging equipment
INDUSTRY BULLETIN
With funding a priority for the industry,
considerable growth of the infrastructure
supporting the EV charging market is expected.
https://www.avient.com/sites/default/files/2022-05/OnColor Non-Phtalate Color Concentrates for PVC Formulations Product Bulletin.pdf
PRODUCT SPECIFICATION
PRODUCT BULLETIN
CARRIER PVC
Recommended % of use 1%
Temperature resistance 200°C
Dispersion - abaque Avient ≤ 2
Copyright © 2022, Avient Corporation.
https://www.avient.com/sites/default/files/2024-09/Garage Door Composite Panel Application Bulletin.pdf
POLYSTRAND™ THERMOPLASTIC PANELS
MATERIALS AND CHARACTERISTICS
Facesheet Resins Polypropylene (PP)
PETG
Facesheet
Reinforcement Glass Fiber
Core Materials PET Foam
PP Honeycomb
Characteristics
Lightweight
Excellent Impact Resistance
Formable
Value Engineered Facesheets
Recyclable
2-layer
Composite Laminate
Unidirectional Composite
Tape
3-layer
Composite Laminate
0°/90°/0°
4-layer
Composite Laminate
0°/90°/90°/0°
POLYSTRAND™ CONTINUOUS FIBER LAMINATES
Configuration
Wood & Polystrand X-ply
Aluminum & Polystrand X-ply
Common Material Reinforcements
POLYSTRAND™ COMPOSITE SANDWICH PANELS
Configuration
Fiber Reinforced Facesheet
Fiber Reinforced Facesheet
Core Material
https://www.avient.com/sites/default/files/2021-08/20210802-business-profile.pdf
Date Registered
ID
Officers/Authorised Representative(s)
Position Held
Nationality/CitizenshipName
Date of Appointment
XU TAO EB6238077 CHINESE 30/06/2021ACRA
DirectorROOM 102, BUILDING 20, SUB LANE 7, LANE
888, LUOJIN ROAD
SHANGHAI, 201104, CHINA
CHAN BAI RONG S8534833G SINGAPORE CITIZEN 30/06/2021ACRA
Director10A BENDEMEER ROAD
#26-103
BENDEMEER LIGHT
SINGAPORE (331010)
LEE SAY ENG A52290094 MALAYSIAN 30/06/2021ACRA
Page 2 of 4
ID
Officers/Authorised Representative(s)
Position Held
Nationality/CitizenshipName
Date of Appointment
Director168 JINAN ROAD, BUILDING 10, ROOM 802,
SHANGHAI
CHINA 200021
CHAN LAI YIN S7480587F MALAYSIAN 28/06/2010ACRA
Secretary26 SIMEI STREET 1
#11-08
MELVILLE PARK
SINGAPORE (529947)
LEE WEI HSIUNG S7927166G SINGAPORE CITIZEN 01/12/2009ACRA
Secretary633 JURONG WEST STREET 65
#10-310
SINGAPORE (640633)
Shareholder(s)
Name
ID Nationality/Citizenship
Place of incorporation/
Origin/Registration
Address Changed
AVIENT CORPORATION T05UF0103G UNITED STATES OF AMERICA ACRA1
33587 WALKER ROAD, AVON LAKE,
OHIO 44012,
UNITED STATES OF AMERICA
Ordinary(Number) Currency
694600 SINGAPORE, DOLLARS
Ordinary(Number) Currency
7200000 UNITED STATES OF AMERICA, DOLLARS
Page 3 of 4
Abbreviation
UL - Local Entity not registered with ACRA
UF - Foreign Entity not registered with ACRA
AR - Annual Return
AGM - Annual General Meeting
FS - Financial Statements
OSCARS - One Stop Change of Address Reporting Service by Immigration & Checkpoint Authority.
https://www.avient.com/sites/default/files/2025-03/CAI Solutions for Recycled Resins in E_E Applications Product Bulletin _A4.pdf
Cesa™ Flame Retardant Additives enable a
fire performance in line with different levels
of Glow Wire temperatures (IEC 60685-2-12)
for various recycled resins including PP, PC,
and PS.
https://www.avient.com/sites/default/files/2020-09/lubrione-processing-guide.pdf
BASE
RESIN PPA PC PSU PES PPS
CO-
POLYMER
ACETAL
PEEK PA
Barrel Temperatures* °F (°C)
Rear Zone 550–580
(288–305)
520–560
(271–293)
600–640
(316–338)
630–660
(332–338)
550–580
(288–304)
350–370
(177–188)
660–700
(349–371)
440–490
(227–254)
Center Zone 560–600
(293–316)
530–570
(277–299)
620–670
(327–354)
650–680
(343–360)
560–615
(293–324)
380–390
(193–200)
700–730
(371–388)
470–510
(243–266)
Front Zone 580–620
(304–327)
550–580
(288–305)
630–680
(332–360)
670–730
(354–388)
590–630
(310–332)
390–430
(200–221)
720–750
(382–400)
490–540
(254–282)
Nozzle 575–615
(302–324)
550–600
(288–316)
630–680
(332–360)
680–700
(360–371)
600–625
(316–330)
380–415
(193–213)
720–750
(382–400)
520–570
(271–300)
Melt
Temperature
575–615
(302–324)
560–600
(293–316)
625–675
(330–358)
650–710
(343–377)
600–625
(316–330)
370–410
(188–210)
670–740
(354–393)
520–570
(271–300)
Mold
Temperature
250–300
(121–150)
175–240
(80–116)
190–300
(88–150)
225–325
(107–164)
250–325
(121–164)
150–225
(66–107)
290–375
(143–190)
150–200
(66–93)
Pack & Hold
Pressure
50%–75%
of Injection Pressure
Injection
Velocity
in/s
1.0–3.0
Back Pressure
psi 50
Screw Speed
rpm 50–90
Drying
Parameters
°F (°C)
6 hrs @ 175
(80)
4 hrs @ 250
(121)
4 hrs @ 275
(135)
4 hrs @ 300
(150)
4 hrs @ 250
(121)
2 hrs @ 200
(93)
3 hrs @ 300
(150)
4 hrs @ 180
(82)
Allowable
Moisture
%
< 0.05 < 0.02 < 0.02 < 0.04 < 0.02 0.15–0.20 < 0.02 0.10–0.20
Cushion
in 0.125–0.250
Screw
Compression
Ratio
2.5:1–3.5:1 2.0:1–2.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1
Nozzle
Type
General
General
General
General
General
General
General
Reverse
Taper
Clamp
Pressure 5–6 Tons/in2 of projected area of cavities and runner system
* Barrel temperatures should be elevated for compounds designed for electrical insulative properties.
Draft Angle • Maintain a minimum draft angle of 1/2° per side.
https://www.avient.com/sites/default/files/2020-09/edgetek-processing-guide.pdf
Base Resin PPA PC PSU PES PPS
Co-
polymer
Acetal
PEEK PA
Barrel Temperatures* °F (°C)
Rear Zone 550–580
(288–305)
550–590
(288–310)
600–640
(316–338)
630–660
(332–338)
550–580
(288–304)
350–370
(177–188)
660–700
(349–371)
440–490
(227–254)
Center Zone 560–600
(293–316)
570–600
(300–316)
620–670
(327–354)
650–680
(343–360)
560–615
(293–324)
380–390
(193–200)
700–730
(371–388)
470–510
(243–266)
Front Zone 580–620
(304–327)
580–630
(304–322)
630–680
(332–360)
670–730
(354–388)
590–630
(310–332)
390–430
(200–221)
720–750
(382–400)
490–540
(254–282)
Nozzle 575–615
(302–324)
580–630
(304–322)
630–680
(332–360)
680–700
(360–371)
600–625
(316–330)
380–415
(193–213)
720–750
(382–400)
520–570
(271–300)
Melt
Temperature
575–615
(302–324)
580–625
(304–330)
625–675
(330–358)
650–710
(343–377)
600–625
(316–330)
370–410
(188–210)
670–740
(354–393)
520–570
(271–300)
Mold
Temperature
250–300
(121–150)
175–240
(80–116)
190–300
(88–150)
225–325
(107–164)
250–325
(121–164)
190–250
(88–121)
290–375
(143–190)
150–200
(66–93)
Pack & Hold
Pressure
50%–75%
of Injection Pressure
Injection
Velocity
in/s
1.0–3.0
Back Pressure
psi 50
Screw Speed
rpm 50–90
Drying
Parameters
°F (°C)
6 hrs @ 175
(80)
4 hrs @ 250
(121)
4 hrs @ 275
(135)
4 hrs @ 250
(121)
3 hrs @ 300
(150)
2 hrs @ 200
(93)
3 hrs @ 275
(135)
4 hrs @ 180
(82)
Cushion
in 0.125–0.250
Screw
Compression
Ratio
2.5:1–3.5:1 2.0:1–2.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1
Nozzle
Type
General
General
General
General
General
General
General
Reverse
Taper
Clamp
Pressure 5–6 Tons/in2 of projected area of cavities and runner system
* Barrel temperatures should be elevated for compounds designed for electrical insulative properties.
Draft Angle • Maintain a minimum draft angle of 1/2° per side.
https://www.avient.com/sites/default/files/resources/PolyOne%2520India%2520Terms%2520and%2520Conditions%2520of%2520Sale%2520of%2520Products.May%25202016.pdf
Seller
makes no other warranties extending beyond the description of the
Product, whether used alone or in combination with any other substance
or in any process.
2.
Either party may suspend performance hereunder (except to
pay for Product already received) in the event of: (1) acts of God, fire,
explosion, flood, hurricanes; (2) strikes, lockouts or other industrial
disturbances or riots; (3) war, declared or undeclared, or acts of terrorism; (4)
compliance with any Federal, state, provincial, municipal or military law,
regulation, order, or rule, foreign or domestic, including priority, rationing,
allocation or preemption orders or regulations, or cancellation of Seller’s or
Buyer’s license to operate its plant; (5) catastrophic failure of facilities used
to manufacture Product, interruption or shortage of transportation, labor,
power, fuel or raw materials; (6) total or partial shutdown due to Seller’s
normal plant turnaround; or (7) any other cause or causes of any kind or
character reasonably outside the control of the party failing to perform,
whether similar or dissimilar from the enumerated causes (a “force
majeure”).