https://www.avient.com/sites/default/files/2023-01/ECCOH XL Cross-Linkable Solutions for Photovoltaic Cable _8148_ Product Bulletin.pdf
ECCOH™ XL Cross-Linkable Solutions
for Photovoltaic Cables
Enabling a more sustainable and safer planet, Avient
has developed ECCOH™ XL Cross-Linkable Solutions
for photovoltaic cable applications (ECCOH XL 8148).
KEY CHARACTERISTICS
UV and Weather Resistance - ECCOH XL 8148
solutions are suitable for permanent outdoor use.
Flame Retardant Performance - ECCOH XL 8148
cable solutions are non-halogen flame retardant
offering low smoke and fume performance.
https://www.avient.com/sites/default/files/2021-11/eccoh-5565-antenna-power-cable.pdf
CABLE
MANUFACTURER
A N T E N N A P O W E R C A B L E
• Elongation at -40°C
• High temperature bend test at 130°C
• Low water absorption
• Resistance to braided shielding
• Fire performance to pass CPR class Dca
• Provided best cold performance compared
to competitor solutions
• Enabled faster processing with increased
line speed
• Met material fire performance requirements
and all other performance criteria
ECCOH™ 5565 Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable manufacturer
https://www.avient.com/resource-center?document_type=59&document_subtype=127&industry=0&product_family=81&product_subfamily=0&product_name=0&op=FILTER RESULTS&form_build_id=form-Ojq3VtEkRrXIsgZSyKvAgO_Z3JHuKtjJLR7xfOXoAI8&form_id=resource_filter_form&page=1
ECCOH XL 8148 for Photovoltaic Cable
ECCOH™ 5702 SEPAP - Riser Cables
ECCOH™ LSFOH 5924 - FTTA Cable
https://www.avient.com/resource-center?document_subtype=127&document_type=59&form_build_id=form-Ojq3VtEkRrXIsgZSyKvAgO_Z3JHuKtjJLR7xfOXoAI8&form_id=resource_filter_form&industry=0&op=FILTER RESULTS&product_family=81&product_name=0&product_subfamily=0&page=1
ECCOH XL 8148 for Photovoltaic Cable
ECCOH™ 5702 SEPAP - Riser Cables
ECCOH™ LSFOH 5924 - FTTA Cable
https://www.avient.com/sites/default/files/2024-06/ECCOH 5981 for Teck 90 Cables Product Bulletin.pdf
ECCOH™ Low Smoke & Fume Non-Halogen Formulation 5981
UV and chemically resistant thermoplastic for Teck 90 cable outer jackets
ECCOH 5981 UV thermoplastic is a cost-effective
material for jacketing, combining high environmental
stress crack resistance (ESCR), UV performance, good
shear strength, and flame-retardant properties for
low-voltage, armored cables.
The ECCOH
5981 UV grade prevents cracking, absorbs stress,
withstands low temperatures, and resists chemicals,
helping to reduce damage to cable construction,
mitigate risks during installation and use, and avoid
costly field repairs.
Offering excellent mechanical properties, the ECCOH
5981 UV formulation provides a durable material
choice for Teck 90 cables used in demanding
locations where safety is paramount.
https://www.avient.com/sites/default/files/2022-07/ECCOH_ LSFOH 5924 - FTTA Cable - Application Snapshot.pdf
CABLE
MANUFACTURER
H Y B R I D F T T A C A B L E
• Elongation at -40°C
• High temperature bend test at 130°C
• Low water absorption
• Resistance to braided shielding
• Fire performance to pass CPR class Dca
• Provided superior environmental stress
crack resistance (ESCR) and performance
at cold temperatures, increasing cable
lifetime
• Improved cable flexibility for easier
installation
• Enabled faster processing at increased line
speed
ECCOH™ LSFOH 5924 Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable manufacturer
https://www.avient.com/sites/default/files/2024-10/ECCOH_ LSFOH 5806 Formulation - Power Cable Jacket - Application Snapshot.pdf
CABLE
MANUFACTURER
C A B L E J A C K E T
• Operating temperature from -40°C to 70°C
• High gel resistance
• Low shrinkage
• Strippable for easy installation
• Good flame retardancy
• Developed a formulation with oil resistance as per
the NEK 606 technical specification
• Allowed our customer to use the same cable
design in various climates due to its wide
operating temperature range
• Provided expertise to improve manufacturing
efficiencies, helping the customer achieve higher
processing speeds
ECCOH LSFOH 5806 Formulation
KEY REQUIREMENTS
WHY AVIENT?
AVIENT SOLUTION
HIGH CHEMICAL RESISTANCE
LEARN MORE
© 2024 Avient Corporation, All Rights Reserved
https://www.avient.com/products/engineered-polymer-formulations/sustainable-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable manufacturer
https://www.avient.com/sites/default/files/2024-10/ECCOH_ LSFOH 5983 Formulation - Power Cable Jacket - Application Snapshot.pdf
CABLE
MANUFACTURER
J A C K E T F O R P O W E R C A B L E
• High tear resistance > 11 N/mm
• High environmental stress cracking resistance (ESCR)
• Cost efficient solution
• Hot pressure resistance above 80°C
• Provided a jacket solution that complies with
LTS1 requirements as per the BS 7655-6.1
standard
• Enabled use in over-armored cables operating
at a maximum conductor temperature of 90°C
• Supported our customer in optimizing the
processing of the new material
ECCOH LSFOH 5983 Formulation
KEY REQUIREMENTS
WHY AVIENT?
AVIENT SOLUTION
HIGH ESCR + TEAR RESISTANCE
LEARN MORE
© 2024 Avient Corporation, All Rights Reserved
https://www.avient.com/products/engineered-polymer-formulations/sustainable-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable manufacturer
https://www.avient.com/resource-center?document_type=59&document_subtype=127&industry=0&product_family=81&product_subfamily=0&product_name=0&op=FILTER RESULTS&form_build_id=form-Ojq3VtEkRrXIsgZSyKvAgO_Z3JHuKtjJLR7xfOXoAI8&form_id=resource_filter_form&page=2
ECCOH™ 5806 - Gel Filled Tight Buffer Aerial Cable
ECCOH 5161 - OFC Blowing Application in Railways
ECCOH™ 5970 - Thin FTTH Cables
https://www.avient.com/sites/default/files/2020-11/eccoh-product-selection-guide-en.pdf
ECCOH™
LOW SMOKE AND FUME,
NON-HALOGEN
FORMULATIONS
PRODUCT SELECTION GUIDE
ECCOH™ Low Smoke and Fume, Non-Halogen Solutions
*Dry Silane abbreviated as DS
**Cross-linked using Sioplas method
5549 UV Teck-90 5700 5801 UV 5865 5982 UV 6010 6151 6638 UV XLS 8001
APPLICATION
Type Jacket Jacket Jacket Jacket Jacket Jacket Insulation Tight buffer,
Micro-tube Jacket Jacket
CABLE
Type LV, Data LV LV, Data, OFC LV, Data, OFC Data, OFC LV, OFC LV OFC Data, OFC LV
MARKETS
Type B & C, Industrial Industrial, Teck-90 B & C, Industrial Industrial, Oil & Gas,
Shipboard B & C B & C, Industrial Automotive B & C, Industrial B & C, Industrial B & C, Shipboard
Cross-linked No No No Yes No No Yes No No Yes
Cross-linking Method* N/A N/A N/A DS/E-beam N/A N/A DS/E-beam N/A N/A Sioplas
GENERAL PROPERTIES
Properties as Thermoset x x x
SG g/cm³ 1.59 1.54 1.60 1.50 1.57 1.52 1.38 1.46 1.48 1.48
MFI, 150°C/21.6 Kg g/10 min 2.8 5 6 3.5 4 5.9 4.4 6 3 6
Hardness Shore D 44 54 50 46 50 54 56 53 53 49
Tensile psi 1740 2610 1595 1800 1740 2320 3336 2466 2030 2030
Elongation % 160% 200% 136% 133% 180% 150% 145% 160% 175% 160%
LOI % 45% 36% 51% 39% 45% 41% 30% 33% 42% 33%
Low temp brittleness (LTB) °C -26.5°C -49°C -10.5°C -30°C -39°C -38.5°C -41°C -35.5°C -26 -40.5
Max.
Continuous Use Temp °C 90°C 90°C 105°C 90°C 125°C 90°C 90°C 105°C
SMOKE DENSITY (MAX)
Flaming Mode 45 104 312 163 312 118 98 60 101 121
Non-Flaming Mode 212 279 303 416 297 369 296 223 296 393
FEATURES
ESCR x
Flame Performance x x x x x
Heat Resistance x x x
High Char Forming x
Low Temperature
Performance x x
Mechanical Properties x x x
Oil Resistance x
UL Listed Halogen-Free x x x
FEATURES
Wire and Cable
• Highly flame retardant
• Very low toxicity and smoke density
• Many grades are cross-linkable
• Can be processed with color or additive
concentrate, and with UV stabilizer
Pipe and Fittings
• Highly flame retardant
• Very low toxicity and smoke density
• Suitable for extrusion, injection molding
ECCOH™
ECCOH™ non-halogenated formulations
re designed to be highly flame retardant
with extremely low toxicity and smoke
density.