https://www.avient.com/sites/default/files/2021-09/supplier-code-of-conduct-tr.pdf
Avient Tedarikçi Davranış
Kuralları
Avient Corporation ve bağlı şirketleri ve iştirakleri (“Avient”) dünya standartlarında,
sürdürülebilir bir kuruluş olmaya kararlıdır.
https://www.avient.com/sites/default/files/2024-07/LATAM CAI Certifications Bulletin _Spanish_.pdf
© 2024, All Rights Reserved
Avient Corporation
https://www.avient.com/sites/default/files/2023-10/SEM Automotive Aftermarket Rendering Application Bulletin.pdf
Together, we can
elevate the driving experience, surpass expectations,
and shape the future of automotive aftermarket
components.
1.844.4AVIENT
www.avient.com
Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2020-08/advanced-composites-overview-brochure_0.pdf
To learn more about Avient advanced composite solutions, call +1.844.4AVIENT
or visit www.avient.com/composites
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/2020-08/2020-composites-overmolding-overview.pdf
WHEN YOU WORK WITH Avient
From concept to component, you can leverage Avient’s expertise throughout the development cycle in three key
areas: Materials, Processing & Design
D
ES
IG
N
MATERIALS
www.avient.com
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/2020-09/surround-processing-guide-2020.pdf
TEMPERATURE
Material
Rear
°F (°C)
Center
°F (°C)
Front
°F (°C)
Nozzle
°F (°C)
Melt
°F (°C)
Mold
°F (°C)
Nylon 6,6
14% NiCF
540–570
(280–300)
530–560
(275–290)
530–560
(275–290)
540–570
(280–300)
540–570
(280–300)
200–300
(90–150)
Nylon 6,6
30% SS
540–570
(280–300)
530–560
(275–290)
530–560
(275–290)
540–570
(280–300)
540–570
(280–300)
200–300
(90–150)
PBT
14% NiCF
510–410
(265–280)
490–540
(255–280)
480–530
(250–275)
480–530
(250–275)
480–530
(250–275)
150–250
(65–120)
PC
14% NiCF
540–570
(280–300)
540–570
(280–300)
530–560
(275–290)
530–560
(275–290)
530–560
(275–290)
150–250
(65–120)
ABS
14% NiCF
470–520
(240–270)
460–520
(240–270)
460–520
(240–270)
460–530
(240–275)
460–530
(240–275)
100–200
(40–90)
PP
14% NiCF
440–480
(225–250)
440–480
(225–250)
430–470
(220–245)
420–460
(215–240)
420–460
(215–240)
125–175
(50–80)
DRYING
Material
Temperature
°F (°C)
Time
Minimum
Moisture
Maximum
Moisture
Nylon 6,6
14% NiCF
180 (80) 4–5 hours 0.05% 0.20%
Nylon 6,6
30% SS
180 (80) 4–5 hours 0.05% 0.20%
PBT
14% NiCF
250 (120) 6-8 hours 0.02% 0.03%
PC
14% NiCF
250 (120) 3–4 hours 0.02% 0.02%
ABS
14% NiCF
200 (90) 2–4 hours 0.05% 0.10%
PP
14% NiCF
180 (80) 2–4 hours 0.20% 0.30%
Equipment
• Feed throats smaller than 2.5" may cause bridging due to pellet size
- Larger feed throats will be more advantageous with long fiber EMI shielding resins
• General purpose metering screw is recommended
- Mixing/barrier screws are not recommended
• L/D ratio
- 18:1–20:1 (40% feed, 40% transition, 20% metering)
• Low compression ratio
- 2:1–3:1
• Deep flights recommended
- Metering zone 3.5 mm
- Feed zone 7.5 mm
• Check ring
- Three-piece, free-flowing check ring
• General purpose nozzle (large nozzle tips are recommended)
- Minimum orifice diameter of 7/32"
- Tapered nozzles are not recommended for long fiber EMI shielding resins
• Clamp tonnage:
- 2.5–5 tons/in2
Gates
• Large, free-flow gating recommended
- 0.25" x 0.125" land length
- 0.5" gate depth
Runners
• Full round gate design
• No sharp corners
• Minimum of 0.25" diameter
• Hot runners can be used
PROCESSING
Screw Speed Slower screw speeds are recommended to protect fiber length
Back Pressure Lower back pressure is recommended to protect fiber length
Pack Pressure 60–80% of max injection pressure
Hold Pressure 40–60% of max injection pressure
Cool Time 10–30 seconds (depends on part geometry and dimensional stability)
PROCESS CONSIDERATIONS
Recommended – retain fiber length (maximize conductivity)
• Low shear process
• Low screw speed and screw RPM
• Slow Injection speed
• Fill to 99–100% on first stage of injection
- Reduces potential nesting of fibers at gate location
- Improves mechanical performance near gate location
- Promotes ideal fiber orientation
Resin Rich Surface
• Achieved when using a hot mold temperature and longer cure times
≥ Max mold temperature recommendation
• Improved surface aesthetic
• Reduced surface conductivity
• Could reduce attenuation performance in an assembly
Fiber Rich Surface
• Achieved when using a cold mold temperature and shorter cure times
≤ Minimum mold temperature recommendation
• Improved surface aesthetic
• Reduced surface conductivity
• Could improve attenuation performance in an assembly
www.avient.com
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/2023-10/Wire _ Cable Tri-fold Selection Guide_0.pdf
PRODUCT SELECTION GUIDE
WIRE & CABLE
SOLUTIONS
Specialty Engineered
Materials
High performance insulation, jacketing,
and cross-web formulations for the
wire and cable industry
Syncure™ XLPE Cross-linkable
Polyethylene Formulations
• Ambient curing
• Flame performance
• Resistant to heat, oil, creep,
& abrasion
• Low temperature properties
• Low capital investment
• High extrusion speeds
• DBDPE-free grades available
• UL/CSA bulletins
Maxxam™ FR Flame Retardant
Polyolefin Formulations
• FEP alternative
• Fire performance
• UL 444 & plenum yellow
card compliance
• Low dielectric
• High extrusion speeds
• Thin wall extrudability
Maxxam™ SY Foamable Flame
Retardant Formulations
• Low dielectric
• Uniform cell structure
• Crush & heat resistance
• Ease of chemical foaming
ECCOH™ Low Smoke and Fume
Non-Halogen Formulations
• Improved fire safety
• Low smoke, fume, non-halogen
(LSFOH) formulations
• Chemical resistance
ECCOH™ XL Cross-Linkable Solutions
• Non-halogen, low smoke, toxicity,
& corrosiveness
• Excellent mechanical & electrical
properties
• Easily processed
• Operating temperature of 90°C
• Moisture cure technology
Synprene™ Flame Retardant
Thermoplastic Elastomers
• Flexibility
• Flame performance
• Low temperature
brittleness (LTB) resistance
• Chemical resistance
• Easily colored
FireCon™ CPE Insulation Jacketing
Formulations
• Resistance to harsh environments
• Low temperature performance
• Flame performance
• High extrusion speeds
• Sunlight resistance
FEATURES SPECIFICATION
ECCOH™ XL 8148 Non-halogen, low smoke, toxicity, & corrosiveness EN50618
Syncure™ S100FH Horizontal flame UL 44
Syncure™ S100FH-XUV Horizontal flame, UV resistant UL 44
Syncure™ S100FH-UV Horizontal flame, FV-1 flame, UV resistant UL 44, UL 4703
Syncure™ S100FV VW-1 flame UL 44
Syncure™ S100FV-UV VW1, UV resistant UL 44
Syncure™ S112NA Non-flame retardant CSA 22.2
Syncure™ S120NA Non-flame retardant NSF 61
Syncure™ S200FH Horizontal flame, DBDPE-free UL 44
Syncure™ S200FV VW-1, DBDPE-free UL 44
INSULATION FOR POWER CABLE SYSTEMS
Low Voltage Power Cables
• Flame performance
• Resistance to heat, oil, creep, & abrasion
• Low temperature performance
• Low capital investment
• High extrusion speeds
INSULATION & CROSS-WEBS FOR DATA CABLE SYSTEMS
Category Cables
• FEP alternative
• Flame performance
• Low dielectric constant
• High extrusion speeds & thin wall capability
• Chemical resistance
• Low temperature performance
• Flexibility
FEATURES SPECIFICATION
Maxxam™ FR 0521-48 R1 Low smoke & fume, non-halogen UL 444
Maxxam™ FR 0587-21 R3 Halogenated to plenum performance UL 444
Optical Fiber Cables
• Resistance to harsh environments, chemicals, & sunlight
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
FEATURES SPECIFICATION
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen Meets customer-specific flame requirements
Coaxial Cables
• Flexibility
• High extrusion speeds
• Low dielectric constant
• Uniform cell structure
• Crush & heat resistance
FEATURES SPECIFICATION
Maxxam™ SY 89-22-7 Foamable Meets customer-specific flame requirements
JACKETING FOR POWER & DATA CABLE SYSTEMS
Low & Medium Voltage Jacketing
• Resistance to harsh environments, chemicals, & UV degradation
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
• Easily colored
FEATURES SUBMARKETS & USES
FireCon™ CPE 30-33 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear
FireCon™ CPE 37-36 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear
FireCon™ CPE 30-20 RoHS Natural Flame retardant, flexible Building & construction, industrial, nuclear
ECCOH™ 5549 UV Low smoke & fume, non-halogen, flame retardant Building & construction, industrial
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen, flame retardant Optical fiber, ducts
ECCOH™ 5981 UV Low smoke & fume, non-halogen, flame retardant Industrial, Teck 90 wire
Synprene™ RT5180 Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT5180UV Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT3870M Flame retardant, LTB resistance Building & construction, industrial
1.844.4AVIENT
www.avient.com
Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2021-12/PREPERM _ Edgetek Low-loss Dielectric Thermoplastics Technical Bulletin.pdf
KEY PROPERTIES AND PERFORMANCE
FR GRADES H GRADES PEEK GRADES LCP GRADES FLEX GRADES
PROPERTIES CONDITION ISO UNIT PPE400FR PPE700FR PPE950FR PPE1200FR H1500HF H2300HF PEEK700 PEEK900 PEEK1000 PEEK1200 LCP650 LCP800 LCP950 FLX400 FLX700 FLX1100
Dielectric Constant (Dk) 2.4 GHz 4.0 7.0 9.5 12.0 15.0 23.0 7.0 9.0 10.0 12.0 6.5 8.0 9.5 4.0 7.0 11.0
Loss Tangent (Df) 2.4 GHz 0.0030 0.0039 0.0042 0.0045 0.0010 0.0037 0.0024 0.0025 0.0024 0.0027 0.0043 0.0045 0.0047 0.0010 0.0009 0.0012
Density 1183 g/cm3 1.44 1.97 2.20 2.50 2.60 3.40 1.94 2.20 2.30 2.40 2.00 2.15 2.30 1.52 1.93 2.50
Melt Flow Index (MFI)
5 kg, 300 °C
(unless noted)
1113 g/10 min 17 12 13 5 5 8 15 @ 380 °C 13 @ 380 °C 10 @ 380 °C 6 - - - 11 @ 230 °C 2 @ 230 °C 0.3 @ 230 °C
Tensile Strength at Break 23 °C/73 °F 527 MPa 47 52 44 45 23 40 64 62 65 67 75 80 75 11 17 25
Flexural Modulus 23 °C/73 °F 178 MPa 3100 4500 - 9300 2100 5000 6200 7600 9200 11000 8000 8500 8500 1400 1600 2900
Unnotched Izod 23 °C/73 °F 180 kJ/m2 NB 42 20 9 17 10 28 25 18 15 31 20 12 NB NB NB
-20 °C/-4 °F 180 kJ/m2 - - - - 17 10 - - - - - - - - -
Notched Izod 23 °C/73 °F 180 kJ/m2 14 6 4 3 5 4 6 4 4 4 10 6 4 59 23 13
-20 °C/-4 °F 180 kJ/m2 - - - - 5 4 - - - - - - - - - -
STANDARD GRADES RADOME GRADES
PROPERTIES CONDITION ISO UNIT PPE260 PPE300 PPE320 PPE350 PPE400 PPE440 PPE500 PPE650 PPE800 PPE950 PPE1200 RS260 RB260 RS265FR
Dielectric Constant (Dk) 2.4 GHz 2.6 3.0 3.2 3.5 4.0 4.4 5.0 6.5 8.0 9.5 12.0 2.6 2.6 2.7
Loss Tangent (Df) 2.4 GHz 0.0009 0.0009 0.0010 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0010 0.0009 0.0012 0.0032
Density 1183 g/cm3 1.07 1.18 1.21 1.27 1.43 1.50 1.62 1.86 2.10 2.20 2.40 1.06 1.08 1.09
Melt Flow Index (MFI) 5 kg, 300 °C 1113 g/10 min 15 15 16 14 14 14 15 11 10 4 2 21 16 25
Tensile Strength at Break 23 °C/73 °F 527 MPa 40 45 47 50 50 48 45 43 37 37 36 50 42 52
Flexural Modulus 23 °C/73 °F 178 MPa 2700 2400 2000 2600 2800 2700 2600 2600 2300 2600 2600 2200 2200 2600
Unnotched Izod 23 °C/73 °F 180 kJ/m2 NB NB NB NB NB NB NB NB 50 28 24 NB NB NB
-20 °C/-4 °F 180 kJ/m2 NB NB NB NB NB NB NB 50 47 27 25 NB NB NB
Notched Izod 23 °C/73 °F 180 kJ/m2 8 55 69 35 22 20 15 9 8 5 4 19 14 11
-20 °C/-4 °F 180 kJ/m2 8 15 20 14 12 10 9 8 8 5 4 10 12 10
PREPERM™ SERIES
PROPERTIES CONDITION ISO UNIT 8027 8025 8037 8019 8028 8026 8044 8029 8041 8045 8048 8036 8056 8031
Dielectric Constant (Dk) 1 GHz, 23 °C 3.0 3.1 3.4 3.6 3.8 4.4 4.8 5.3 5.4 5.9 6.0 7.0 7.3 9.0
Loss Tangent (Df) 1 GHz, 23 °C 0.0012 0.0012 0.0008 0.0010 0.0010 0.0010 0.0004 0.0008 0.0006 0.0002 0.0006 0.0007 0.0002 0.0007
Density 1183 g/cm3 1.25 1.26 1.35 1.39 1.45 1.59 1.72 1.75 1.79 1.89 1.88 2.06 2.086 2.25
Melt Flow Index (MFI) 5 kg, 300 °C 1113 g/10 min 16 19 10 11 15 13 10 10 15 15 19 10 18 4.7
Tensile Strength at Break 23 °C/73 °F 527 MPa 59 54 54 62 59 54 52 58 52 45 49 45 37 38
Flexural Modulus 23 °C/73 °F 178 MPa 2780 2560 2850 3060 3350 3700 3157 4300 4320 3137 4150 3370 2560 4200
Notched Izod 23 °C/73 °F 180 kJ/m2 15.3 14 14.8 14 12.6 10.4 9.9 8.6 7.4 7.9 6.6 7.1 6.2 6.8
EDGETEK™ 7600 SERIES
Copyright © 2021, Avient Corporation.
https://www.avient.com/sites/default/files/2022-09/PREPERM for 5G Application Bulletin %281%29.pdf
D
ie
le
ct
ri
c
co
ns
ta
nt
Lo
ss
ta
ng
en
t
D
ie
le
ct
ri
c
co
ns
ta
nt
Frequency [GHz]
Frequency [GHz]
Pallet number (1250 kg/pallet)
PREPERM™ PPE950
PREPERM™ PPE800
PREPERM™ PPE440
PREPERM™ PPE320
PREPERM™ PPE260
-- Dielectric constant target
-- +/- 2%
3 ,7 6
3 ,7 8
3 ,8 0
3 ,8 2
3 ,8 4
3 ,8 6
3 ,8 8
3 ,9 0
3 ,9 2
3 ,9 4
0 1 2 3 4 5 6 7 8
D
ie
le
ct
ri
c
co
n
s
ta
n
t
P a lle t numbe r (1 2 5 0 k g/pa lle t )
D ie le c t ric c o n s t a nt t a rge t +/ - 2 %
0 ,0 0 0
0 ,0 0 2
0 ,0 0 4
0 ,0 0 6
0 ,0 0 8
0 ,0 1 0
0 1 0 2 0 3 0 4 0 5 0 6 0
L
o
s
s
t
a
n
g
e
n
t
F re que nc y [G H z ]
P R E P E R M ® P P E 95 0 P R E P E R M ® P P E 80 0
P R E P E R M ® P P E 44 0 P R E P E R M ® P P E 32 0
P R E P E R M ® P P E 26 0
0 ,0 0 0
0 ,0 0 2
0 ,0 0 4
0 ,0 0 6
0 ,0 0 8
0 ,0 1 0
0 1 0 2 0 3 0 4 0 5 0 6 0
L
o
s
s
t
a
n
g
e
n
t
F re que nc y [G H z ]
P R E P E R M ® P P E 95 0 P R E P E R M ® P P E 80 0
P R E P E R M ® P P E 44 0 P R E P E R M ® P P E 32 0
P R E P E R M ® P P E 26 0
0 ,0 0 0
0 ,0 0 2
0 ,0 0 4
0 ,0 0 6
0 ,0 0 8
0 ,0 1 0
0 1 0 2 0 3 0 4 0 5 0 6 0
L
o
s
s
t
a
n
g
e
n
t
F re que nc y [G H z ]
P R E P E R M ® P P E 95 0 P R E P E R M ® P P E 80 0
P R E P E R M ® P P E 44 0 P R E P E R M ® P P E 32 0
P R E P E R M ® P P E 26 0
Copyright © 2022, Avient Corporation.
https://www.avient.com/sites/default/files/2023-11/2023 Syncure Wire and Cable Product Selection Guide_SPANISH.pdf
CARACTERÍSTICAS
• Curación a temperatura ambiente
• Pirorresistencia
• Resistente al calor, el aceite, la fluencia
lenta y la abrasión
• Propiedades de baja temperatura
• Temperature rating por arriba de 125°C
• Baja inversión de capital
• Alta velocidad de extrusión
• Incluidos en boletines de UL/CSA
www.avient.com
Copyright © 2023, Avient Corporation.