https://www.avient.com/resource-center?document_type=0&form_build_id=form-fNS88LG3BRw1MCsEhxqrGzoCcCISeOxlsDfIOUV4Mx0&form_id=resource_filter_form&industry=0&op=FILTER RESULTS&product_family=84&product_name=0&product_subfamily=0&page=0
Mevopur™ formulations for PCR well plates prevent 'cross-talk' and minimize phosphorescence with optimally dispersed TiO2, while balancing melt flow and physical properties, and ensuring quality through ISO 13485:2016 certification.
https://www.avient.com/resource-center?document_type=59&document_subtype=0&industry=0&product_family=0&product_name=0&op=FILTER RESULTS&form_id=resource_filter_form&page=18
Discover how our Versaflex™ HC TPEs provided the ultra-soft and gel-like feel, optimized performance, and complied with FDA and ISO 10993 requirements.
https://www.avient.com/resource-center?document_subtype=0&document_type=59&form_id=resource_filter_form&industry=0&op=FILTER RESULTS&product_family=0&product_name=0&page=18
Discover how our Versaflex™ HC TPEs provided the ultra-soft and gel-like feel, optimized performance, and complied with FDA and ISO 10993 requirements.
https://www.avient.com/sites/default/files/2024-12/Avient Norwalk A2LA ISO17025-17.pdf
No. 0962.01) 09/05/2023 Page 1 of 1
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
AVIENT CORPORATION
80 North West Street
Norwalk, OH 44857
Craig Polta Phone: 419 660 4278
MECHANICAL
Valid To: September 30, 2025 Certificate Number: 0962.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following tests on plastics:
Test Method(s)
Test Name
ASTM D256; ISO 180 Notched Izod
ISO 179 (1eA) Determination of Charpy Impact
ASTM D523 Gloss
ASTM D618 (Method A) Conditioning of Test Specimens
ASTM D792 (Method A) Specific Gravity
ASTM D1238 (Method B) Melt Flow Rate
ASTM D3012 Thermal Oxidative Stability
ASTM D3641 Injection Molding Test Specimens
FMVSS 302 Flammability
ASTM E1331; SAE J1545 Spectrophotometric Color Difference
SAE J1885 (Rev.
Accredited Laboratory
A2LA has accredited
AVIENT CORPORATION
Norwalk, OH
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories.
This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
https://www.avient.com/sites/default/files/2021-11/0514-02-dec2021.pdf
Avon Lake, OH
for technical competence in the field of
Chemical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories.
This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 28th day of February 2020.
_______________________
Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0514.02
Valid to December 31, 2021
Revised September 21, 2021
0514-02s
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
Test Method or Standard:
Test Description:
0514-02c
https://www.avient.com/sites/default/files/2023-10/LubriOne Product Selection Guide.pdf
Steel – Static 0.25 0.46 0.18 0.15 0.12 0.19 0.11 0.14 0.13 0.24 0.17 0.17
Impact
Notched Izod Impact (23°C,
3.18 mm, Injection Molded) J/m ASTM D256A 41 64(6) 110 107 107 70 80 37 37 75 – 69
Thermal Properties
Heat Deflection Temperature ASTM D648
0.45 MPa °C 215(6) – 250 215 216 184 152 151(6) 153(6) 218(6) – –
1.8 MPa °C 65(6) 239(7) 244(6) 210 210 75 94 81.1(6) 88 197(6) – 135(5)
Electrical Properties
Surface Resistivity ohms/sq ASTM D254 – – – 1.30x1012 1.9x1012 5.2x1012 – – – – – 1.0x109
Dielectric Strength (Short Time) kV/mm – – 8.5 – – – – – – – – –
Flammability
Flame Rating Class UL 94 HB – – HB HB HB – HB – – – –
LubriOne™ Internally Lubricated Formulations
NOTES (1) Type I, 5.1mm/min
(2) Type I, 21.3 mm/min
(3) Type I, 50 mm/min
(4) Type I, 5.1mm/min, Break
(5) 3.2 mm thick, Unannealed
(6) 6.35 mm thick, Unannealed
(7) 3.2 mm thick, Annealed
PRODUCT DESCRIPTION UNITS TEST
METHOD
5024 RS HI
5021 RS S1
5021 RS X2
5019 X1
LB6700-
5001 RS AF
Black
NN-
000/01M
Black SO
REC
LB6600-
5030 RS
Grey
LB3300-
5010 RS
LB3300-
5005 RS
REC
LB3220-
5001 RS C
Natural X1
5010 GP
Grey
5006 RS PE
5004 RS PE
LB4200-
5022 Black
LB4200-
5023
Base Polymer PA 6 PA6/PA66 PA66 PBT PC PKE POM
Lubricant UHMWPE1 UHMWPE UHMWPE UHMWPE UHMWPE MoS22 Graphite UHMWPE UHMWPE UHMWPE Graphite UHMWPE UHMWPE MoS2 UHMWPE
Filler type GF10 GF30 GF30 GF50 GF50 Unfilled GF33 GF20 MI20 GF10 Unfilled GF20 GF30 Unfilled Unfilled
General Properties
Specific Gravity g/cm3 ISO 1183 1.18 1.35 1.39 1.55 1.58 1.14 1.44 1.42 1.46 1.23 1.26 1.34 1.43 1.4 1.35
Mechanical Properties
Tensile Modulus (23°C) MPa ISO 527-1 4250 9500 9000 15500 16600 3500 10600 6300 3330 4000 1630 5300 9250 2470 2150
Tensile Strength (Yield, 23°C) MPa ISO-527-2 97 150 160 205 200 85 164 102 55 60 60 108 99.1 55 50
Tensile Elongation (Break, 23°C) % ISO-527-2 12 2.5 3 2.7 2.4 3.4 2.0 4.2 8 2.5 46 3.7 1.5 11 11
Flexural Strength (23°C) MPa ISO 178 103 – – 285 265 108 215 127 78 85 38 155 117 73 68
Flexural Modulus (23°C) MPa ISO 178 3250 – – 12400 11100 2690 9000 4700 3000 3100 1380 4600 5450 2210 2070
Impact
Charpy Notched Impact Strength
(23°C, Injection Molded) kJ/m^2 ISO 179 14 12 10 15 10 3 6 7.7 4.3 12 15 10 7.6 8 5
Charpy Unnotched Impact
Strength (23°C, Injection Molded) kJ/m^2 ISO 179 82 55 61 75 60 65 50 47 69 - NB 63 36 NB NB
Thermal Properties
Deflection Temperature Under Load
1.8 Mpa, Unannealed °C ISO 75-2/A 107 – – 204 – 73 235 – – – 90 210 204 86 80
Cofficient of Friction (CoF) & Wear Rate
CoF vs.
https://www.avient.com/sites/default/files/2024-09/24 EN 47.pdf
CERTIFICATE
Signed for the certification body:
Eric Louys
Chairman Certification Committee
CERTIFICATE
EN ISO 50001 : 2018
Energy Management System
VINÇOTTE nv
Jan Olieslagerslaan 35, 1800 Vilvoorde, Belgium
This is to certify that Avient
Located at Rue Melville Wilson 2
5330 Assesse
Belgium
has established and maintains an energy management system according the requirements of
EN ISO 50001 : 2018 “Energy Management System” for:
Design and manufacture of colour and additive concentrates, thermoplastic resins and
speciality compounds
This certificate is based on the result of an energy audit documented in the audit report 61231731.
Certificate number: 24 EN 47
Valid from 1 February 2024 to 31 January 2027
Further clarifications regarding the scope of this certificate and the applicability of EN ISO 50001 : 2018
requirements may be obtained by consulting the organization.
https://www.avient.com/sites/default/files/2023-06/ISO 45001 Suzhou - GLS.pdf
https://www.avient.com/sites/default/files/2021-11/suzhou-colormatrix-iso-900185.pdf
https://www.avient.com/sites/default/files/2023-11/ISO 14001_CN_Changzhou.pdf