https://www.avient.com/resources/safety-data-sheets?page=1822
STAN-TONE EPX-8829 BLACK
https://www.avient.com/resources/safety-data-sheets?page=6818
STAN-TONE EPX-108070 GREEN
https://www.avient.com/resources/safety-data-sheets?page=2934
STAN-TONE EPX-33185 CARBON NANO 2110
https://www.avient.com/resource-center?document_subtype=0&document_type=59&form_id=resource_filter_form&industry=0&op=FILTER RESULTS&product_family=0&product_name=0&page=39
Stan-Tone™ EPX - Product Bulletin
https://www.avient.com/resource-center?document_type=59&document_subtype=0&industry=0&product_family=0&product_name=0&op=FILTER RESULTS&form_id=resource_filter_form&page=41
Stan-Tone™ EPX - Product Bulletin
https://www.avient.com/sites/default/files/2020-08/2020-composites-overmolding-overview.pdf
SPORTING GOODS
Boots, bindings,
protective equipment
MARINE
Hull reinforcement,
seats, paddles
50% Long
Glass Fiber
Reinforced
PP
50% Long
Glass Fiber
Reinforced
PP + 0°
CFRTP
50% Long
Glass Fiber
Reinforced
PP + 0°/90°
CFRTP
50% Long Glass
Fiber Reinforced
PP +
0°/90°/90°/0°
CFRTP
17K 28K 29K
50% Long
Glass Fiber
Reinforced
PP + 0°/90°/0°
CFRTP
29K 31K
+60.7%
FLEXURAL STRENGTH (ASTM D7264)
IMPACT RESISTANCE (ASTM D3763)
50% Long
Glass Fiber
Reinforced
PP
50% Long
Glass Fiber
Reinforced
PP + 0°
CFRTP
50% Long
Glass Fiber
Reinforced
PP + 0°/90°
CFRTP
50% Long
Glass Fiber
Reinforced
PP + 0°/90°/0°
CFRTP
50% Long Glass
Fiber Reinforced
PP +
0°/90°/90°/0°
CFRTP
E
n
e
rg
y
at
T
o
ta
l (
J)
F
o
rc
e
a
t
P
e
ak
(
kN
)
18
16
14
12
10
8
6
4
2
0
6.0
5.9
4.0
3.0
2.0
1.0
0.0
11.2 15.1 14.6 12.7 16.4
1.2 1.9 2.8 4.0 5.0
+58.3%
+34.8%
50% Long
Glass Fiber
Reinforced
PP
50% Long
Glass Fiber
Reinforced
PP + 0°
CFRTP
50% Long
Glass Fiber
Reinforced
PP + 0°/90°
CFRTP
50% Long Glass
Fiber Reinforced
PP +
0°/90°/90°/0°
CFRTP
17K 28K 29K
50% Long
Glass Fiber
Reinforced
PP + 0°/90°/0°
CFRTP
29K 31K
+60.7%
FLEXURAL STRENGTH (ASTM D7264)
IMPACT RESISTANCE (ASTM D3763)
50% Long
Glass Fiber
Reinforced
PP
50% Long
Glass Fiber
Reinforced
PP + 0°
CFRTP
50% Long
Glass Fiber
Reinforced
PP + 0°/90°
CFRTP
50% Long
Glass Fiber
Reinforced
PP + 0°/90°/0°
CFRTP
50% Long Glass
Fiber Reinforced
PP +
0°/90°/90°/0°
CFRTP
E
n
e
rg
y
at
T
o
ta
l (
J)
F
o
rc
e
a
t
P
e
ak
(
kN
)
18
16
14
12
10
8
6
4
2
0
6.0
5.9
4.0
3.0
2.0
1.0
0.0
11.2 15.1 14.6 12.7 16.4
1.2 1.9 2.8 4.0 5.0
+58.3%
+34.8%
Application
design
Modeling &
simulation
Prototyping
& validation
Material
selection
Composite/
resin
compatibility
Custom
formulations
Mold filling analysis
Technical support
Process optimization
PROCESSING
MATERIALS
Material selection is crucial to an
application’s success.
https://www.avient.com/sites/default/files/2023-11/2023 Syncure Wire and Cable Product Selection Guide_SPANISH.pdf
Syncure™ XLPE
Formulaciones Para
Polietileno Reticulable
PARA CABLES DE BAJA TENSIÓN
GUÍA DE SELECCIÓN DE PRODUCTO
Syncure™ XLPE
POLIETILENO RETICULABLE POR HUMEDAD PARA AISLAMIENTO PARA CABLES DE BAJA TENSIÓN
SISTEMA S100FH S100FH-XUV S100FH-UV S100FV S100FV-UV S112NA S120NA S200FH S200FV
Aplicaciones Cable para construcción, bandeja de cables
Cable para construcción,
bandeja de cables
Cable fotovoltaico
(PV)
Cable para construcción,
bandeja de cables
Cable para construcción,
bandeja de cables
Cable para construcción,
Teck-90 Tuberia
Cable para edificaciones,
tray cables,
cables de servicio
Cable para edificaciones,
tray cables,
cables de servicio
Especificaciones UL 44 UL 44 UL 44, UL 4703 UL 44 UL 44 CSA 22.2 Usable para NSF 61 UL 44 UL 44
Tipo de alambre XHHW-2, RHW-2, USE-2, SIS
XHHW-2, RHW-2, USE-2,
SIS
XHHW-2, RHW-2,
USE-2, SIS, PV
XHHW-2, RHW-2,
SIS
XHHW-2, RHW-2,
USE-2, SIS, PV RW-90, Teck-90 –
RHW-2, RHW, RHH,
XHHW-2, XHH, XHHW, SIS RHW, RHH, RHW-2
% de
componentes
83% S1054A
17% V0022G RoHS
83% S1054A
17% V0022G-UV RoHS
70% S1054A
30% V0022G-UV RoHS
50% S1054A
50% V0044G RoHS
50% S1054A
50% V0044G-UV RoHS
95% S1054A
5% S1000B
95% S1016A
5% S1037B
78% S1054A
22% SC5400-0002 RoHS
MB ALT FR
50% S1054A
50% SC5400-0003 RoHS
MB ALT FR
Caracteristicas Flama horizontal
Flama horizontal,
resistencia UV,
posibilidad de colorear
Flama horizontal,
flama FV-1, resistencia UV,
posibilidad de colorear
VW-1 VW-1, resistencia UV, posibilidad de colorear
Sin retardante
a la flama
Para aplicaciones
de tuberia
Flama horizontal,
libre de DBDPE VW-1, libre de DBDPE
PROPIEDADES GENERALES
Gravedad Específica 1.01 1.02 1.10 1.31 1.31 0.92 0.95 1.01 1.31
Rigidez Shore D,
10 Segundos 47 47 47 48 48 47 59 47 48
% de Contenido
de Gel 68 68 70 70 70 72 72 68 70
PROPIEDADES DE RESISTENCIA A LA TRACCIÓN
Resistencia a la
Tracción (psi) 2800 2500 2500 3200 2650 2800 4500 2800 3200
% de Elongación 400 400 400 470 540 400 80 400 470
% de Retención
de Tracción 100 100 97 110 110 95 75 95 100
% de Retención
de Elongación 90 90 94 100 100 90 75 90 93
PROPIEDADES ELÉCTRICAS
Resistencia Dieléctrica
(V/mil) 1000 1400 1400 1200 1200 1000 –– 1000 1200
Constante Dieléctrica 2.31 2.45 2.61 2.61 2.61 2.24 2.1 2.31 2.61
% de Factor
de Disipación 0.0012 0.0080 0.008 0.0043 0.0043 0.0008 0.002 0.0012 0.0043
PROPIEDADES TÉRMICAS
Condiciones Nominales
de Temperatura en °C 90 90 90 90 90 90 125 90 90
% de Deformación
Térmica 10 10 5 5 5 10 10 10 5
La cartera Syncure XLPE es un sistema de dos pasos
de Polietileno reticulable por humedad, injertado con
Silano.
https://www.avient.com/sites/default/files/2024-09/Avient_RY 2023 CDP Verification Opinion Declaration.pdf
Energy:
o Diesel Fuel Consumption: 2,868,323 kWh
o Natural Gas Fuel Consumption: 178,696,287 kWh
o Renewable Energy Consumed - Self Generated (solar): 681,059 kWh
o Renewable Energy Consumed - Self Generated (Wind): 2,385,048 kWh
o Grid Electricity Consumed: 409,650,679 kWh
o Renewable Energy Credits (REC) Purchased: 112,413,420 kWh
o Renewable Electricity Consumed – Offsite: 138,415,253 kWh
Page 2
Period covered by GHG emissions verification:
• January 1, 2023 to December 31, 2023
Global Warming Potential (GWP) and emission factor data sets:
• IPCC GWP: AR6
• USEPA Emission Factor Hub, released 2024
• USEPA eGRID, released 2024
• Final Rule (40 CFR 98) - Industrial Sector 2013
• DEFRA, released 2023
• IEA, released 2023
• European Residual Mix, released 2022 v2.0
GHG Reporting Protocols against which verification was conducted:
• World Resources Institute (WRI)/World Business Council for Sustainable Development (WBCSD)
Greenhouse Gas Protocol, Corporate Accounting and Reporting Standard, Revised Edition (Scope 1 and 2)
and the GHG Protocol Scope 2 Guidance, an amendment to the GHG Protocol Corporate Standard
• WRI/WBCSD Corporate Value Chain (Scope 3) Accounting and Reporting Standard
Verification Protocols used to conduct the verification:
• ISO 14064-3 Second Edition 2019-04: Greenhouse gases - Part 3: Specification with guidance for the
verification and validation of greenhouse gas statements
• Apex’s standard procedures and guidelines for external Assurance of Sustainability Reports and
International Standard on Assurance Engagements (ISAE) 3000 Revised, Assurance Engagements Other
than Audits or Reviews of Historical Financial Information (effective for assurance reports dated on or after
Dec. 15, 2015), issued by the International Auditing and Assurance Standards Board.
https://www.avient.com/sites/default/files/2024-09/Garage Door Composite Panel Application Bulletin.pdf
POLYSTRAND™ THERMOPLASTIC PANELS
MATERIALS AND CHARACTERISTICS
Facesheet Resins
Polypropylene (PP)
PETG
Facesheet
Reinforcement
Glass Fiber
Core Materials
PET Foam
PP Honeycomb
Characteristics
Lightweight
Excellent Impact Resistance
Formable
Value Engineered Facesheets
Recyclable
2-layer
Composite Laminate
0°/90°
Unidirectional Composite
Tape
3-layer
Composite Laminate
0°/90°/0°
4-layer
Composite Laminate
0°/90°/90°/0°
POLYSTRAND™ CONTINUOUS FIBER LAMINATES
Configuration
Wood & Polystrand X-ply
0°/90°
Aluminum & Polystrand X-ply
0°/90°
Common Material Reinforcements
POLYSTRAND™ COMPOSITE SANDWICH PANELS
Configuration
Fiber Reinforced Facesheet
Fiber Reinforced Facesheet
Core Material
https://www.avient.com/sites/default/files/2020-11/eccoh-product-selection-guide-en.pdf
ECCOH™
LOW SMOKE AND FUME,
NON-HALOGEN
FORMULATIONS
PRODUCT SELECTION GUIDE
ECCOH™ Low Smoke and Fume, Non-Halogen Solutions
*Dry Silane abbreviated as DS
**Cross-linked using Sioplas method
5549 UV Teck-90 5700 5801 UV 5865 5982 UV 6010 6151 6638 UV XLS 8001
APPLICATION
Type Jacket Jacket Jacket Jacket Jacket Jacket Insulation
Tight buffer,
Micro-tube
Jacket Jacket
CABLE
Type LV, Data LV LV, Data, OFC LV, Data, OFC Data, OFC LV, OFC LV OFC Data, OFC LV
MARKETS
Type B & C, Industrial Industrial, Teck-90 B & C, Industrial
Industrial, Oil & Gas,
Shipboard
B & C B & C, Industrial Automotive B & C, Industrial B & C, Industrial B & C, Shipboard
Cross-linked No No No Yes No No Yes No No Yes
Cross-linking Method* N/A N/A N/A DS/E-beam N/A N/A DS/E-beam N/A N/A Sioplas
GENERAL PROPERTIES
Properties as Thermoset x x x
SG g/cm³ 1.59 1.54 1.60 1.50 1.57 1.52 1.38 1.46 1.48 1.48
MFI, 150°C/21.6 Kg g/10 min 2.8 5 6 3.5 4 5.9 4.4 6 3 6
Hardness Shore D 44 54 50 46 50 54 56 53 53 49
Tensile psi 1740 2610 1595 1800 1740 2320 3336 2466 2030 2030
Elongation % 160% 200% 136% 133% 180% 150% 145% 160% 175% 160%
LOI % 45% 36% 51% 39% 45% 41% 30% 33% 42% 33%
Low temp brittleness (LTB) °C -26.5°C -49°C -10.5°C -30°C -39°C -38.5°C -41°C -35.5°C -26 -40.5
Max.
Continuous Use Temp °C 90°C 90°C 105°C 90°C 125°C 90°C 90°C 105°C
SMOKE DENSITY (MAX)
Flaming Mode 45 104 312 163 312 118 98 60 101 121
Non-Flaming Mode 212 279 303 416 297 369 296 223 296 393
FEATURES
ESCR x
Flame Performance x x x x x
Heat Resistance x x x
High Char Forming x
Low Temperature
Performance x x
Mechanical Properties x x x
Oil Resistance x
UL Listed Halogen-Free x x x
FEATURES
Wire and Cable
• Highly flame retardant
• Very low toxicity and smoke density
• Many grades are cross-linkable
• Can be processed with color or additive
concentrate, and with UV stabilizer
Pipe and Fittings
• Highly flame retardant
• Very low toxicity and smoke density
• Suitable for extrusion, injection molding
ECCOH™
ECCOH™ non-halogenated formulations
re designed to be highly flame retardant
with extremely low toxicity and smoke
density.