https://www.avient.com/sites/default/files/2020-10/auto-injector-application-study.pdf
Healthcare Solutions
Products and components must meet
regulatory standards and
application-specific demands that
deliver patient safety, security and
comfort.
Requirements:
Heat transfer
Solution:
Trilliant™ Therma-Tech™
Thermally Conductive
Formulations
14.
Requirements:
Thermal conductivity for warming
of medicants
Solution:
Trilliant™ Therma-Tech™
Thermally Conductive
Formulations
Heating system
13
Heat Exchanger
14
Technology Enabled
Design
Connected medical devices are
transforming the way care is
delivered by making it simpler, easier,
more collaborative, and more data
driven.
https://www.avient.com/news/mecall-srl-replaces-lead-trilliant-radiation-shielding-polyone
Replaces Lead with Trilliant™ Radiation Shielding from PolyOne
ANAHEIM, Calif. – PolyOne Corporation (NYSE: POL), a premier global provider of specialized polymer materials, services and solutions, announced that medical device manufacturer Mecall S.r.l. has replaced lead in radiology equipment with Trilliant™ Radiation Shielding solutions from PolyOne.
At working energy levels, the shielding provided by this Trilliant formulation is higher than lead, according to Mecall, resulting in the collimator operator and patient being better protected from unnecessary exposure to radiation.
https://www.avient.com/sites/default/files/2024-07/Ballistic Resistant Composite Panels Product Selection _ Install Guide.pdf
Level
5
7.62mm rifle lead core
full metal copper jacket,
military ball
2750 ft/sec
838 m/sec
1
Level
6
Level
II
9mm full metal jacket
with lead core
1400 ft/sec
427 m/sec
5
Level
7
5.56mm rifle full metal
copper jacket with
lead core
3080 ft/sec
939 m/sec
5
Level
8
Level
III
7.62mm rifle lead core
full metal copper jacket,
military ball
2750 ft/sec
838 m/sec
5
Width Length Thickness Color
LEVEL 1
GlasArmor Panels
36 in/91 cm 96 in/244 cm
0.256 in/6.5 mm Natural
36 in/91 cm 120 in/305 cm
48 in/122 cm 96 in/244 cm
48 in/122 cm 108 in/274 cm
48 in/122 cm 120 in/305 cm
LEVEL 2
GlasArmor Panels
36 in/91 cm 96 in/244 cm
0.384 in/9.8 mm Natural
36 in/91 cm 120 in/305 cm
48 in/122 cm 96 in/244 cm
48 in/122 cm 108 in/274 cm
48 in/122 cm 120 in/305 cm
LEVEL 3
GlasArmor Panels
36 in/91 cm 96 in/244 cm
0.500 in/12.7 mm
Natural
36 in/91 cm 120 in/305 cm Natural
48 in/122 cm 96 in/244 cm Natural, Grey, White, Tan
48 in/122 cm 108 in/274 cm Natural, Grey
48 in/122 cm 120 in/305 cm Natural, Grey, White
ThermoBallistic Panels
24 in/61 cm 96 in/244 cm
0.44 in/11.2 mm White, Grey, Blue
24 in/61 cm 144 in/366 cm
48 in/122 cm 96 in/244 cm
48 in/122 cm 144 in/366 cm
BALLISTIC PANEL SELECTION GUIDE
Customized panel sizes and colors available.
Be sure to wear
appropriate safety equipment including safety
glasses and dust masks when fabricating.
3.
Property GlasArmor Panel ThermoBallistic Panel Test Method
Glass Content 55 wt% 73 wt%
Density
0.066 lb/in3
1.83 g/cm3
0.062 lb/in3
1.72 g/cm3
ASTM D-792
Flex Mod
2.1–2.7 msi
14.5 - 18.6 GPa
2.5 msi
17.2 GPa
ASTM D-790
Flex Strength
65 ksi
448 MPa
14 ksi
96.5 MPa
ASTM D-790
Barcol Hardness 50–60 n/a ASTM D-2583
Fire Rating 1 hour1 n/a ASTM E-119-09c
Flame Spread Rating 452 n/a ASTM E-84-08a
Smoke Developed Rating 1652 n/a ASTM E-84-08a
MATERIAL DATA (TYPICAL VALUES)
1 UL Level 3 panel was fire tested as part of a wall system with steel studs and drywall face sheet
2 NFPA & IBC Class B rating achieved
www.avient.com
Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2020-08/trilliant-case-study-1.pdf
CASE STUDY: TRILLIANT™ HC HIGH PERFORMANCE FORMULATIONS
Ch
all
en
ge
A
cc
ep
te
d.
Trilliant HC High Performance Formulations were
developed for the application needs.
V0 @ 1.5 and 3.0mm
FR PC/ABS failed
0% 20% 40% 60% 80% 100% 120% 140%
Virex TB
Clorox
Broad
Spectrum
CaviCide
SaniCloth
Plus
wipes
1% strain not tested
1% strain not tested
FR PC/ABS failed
FR PC/ABS failed
FR PC/ABS failed
FR PC / ABS (1.0% Strain)
FR PC / ABS (1.5% Strain)
Trilliant HC (1.0% strain)
Trilliant HC (1.5% strain)
FR PC/ABS failed
0% 20% 40% 60% 80% 100% 120% 140%
Virex TB
Clorox
Broad
Spectrum
CaviCide
SaniCloth
Plus
wipes
1% strain not tested
1% strain not tested
FR PC/ABS failed
FR PC/ABS failed
FR PC/ABS failed
FR PC / ABS (1.0% Strain)
FR PC / ABS (1.5% Strain)
Trilliant HC (1.0% strain)
Trilliant HC (1.5% strain)
TENSILE STRENGTH RETENTION
AFTER 7 DAYS EXPOSURE
Both materials were tested according to ASTM D543 for 7 days.
https://www.avient.com/resources/safety-data-sheets?page=4148
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/sites/default/files/2021-12/Chemically Resistant Materials Whitepaper.pdf
The data in these tables clearly
shows that the Trilliant HC8900 and Edgetek ET8900
series outperformed the competitive materials
across all different disinfectant/cleaner types.
The
Trilliant HC8900 and Edgetek ET8900 series are
polymer blends based on linear aliphatic PK.
Resistance ratings for Trilliant HC8900 series and competing materials against common healthcare disinfectants
https://www.avient.com/sites/default/files/2023-01/Disinfectant Resistant Trilliant and Versaflex HC Materials Program Bulletin_0.pdf
Virex® Tb Vesphene™ IIse CaviCide™
Trilliant™ HC 8910 +++ +++ +++
Trilliant™ HC 8920 (FR) – +++ +++
FR PC/PET – + ++
FR COPE (copolyester) + ++ +++
Tensile Strength Property Retention After 72-hour Continuous Exposure
+++ Best (>90% retention),
++ Better (50-90% retention),
+ Good (
Specifically formulated to bond tightly to the semi-crystalline Trilliant HC
substrate, Versaflex HC OM 8940 demonstrated excellent peel strength (also known as bond strength).
Average Peel Strength (PLI) Versaflex™ HC OM 8940
Trilliant™ HC 8910 16.3
Trilliant™ HC 8920 FR 17.0
https://www.avient.com/sites/default/files/2021-04/trilliant-hc-conductive-pipette-case-study.pdf
CUSTOM
FORMULATION
IMPROVES
PRODUCTIVITY AND
MANUFACTURING
EFFICIENCY
CASE STUDY: TRILLIANT™ HC SPECIALTY ENGINEERED MATERIALS
Ch
all
en
ge
A
cc
ep
te
d.
THE IMPACT
For the manufacturer, Trilliant™ HC specialty engineered
materials provided a number of advantages that
contributed to the success of the new product line:
• Reduced Cycle Time: The high flow properties
of the Trilliant HC formulation allowed the
manufacturer to produce warp-free parts that
require less packing and cooling time, resulting
in a 40% cycle time reduction
Through customer intimacy, Avient’s Trilliant HC
formulations offered an effective solution that allowed
the manufacturer to improve its bottom line and
increase its operating income.
https://www.avient.com/resources/safety-data-sheets?page=5783
Trilliant HC2020-0002 FR Grey
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/sites/default/files/2023-01/Trilliant HC GF Polyketone _PK_ Product Bulletin.pdf
Trilliant™ HC Healthcare Thermoplastics
Glass-filled Polyketone Formulations
This Trilliant™ HC glass-filled (GF) series consists
of specialty engineered, polyketone (PK)
thermoplastics.
PRODUCT BULLETIN
PROPERTY COMPARISON
TRILLIANT HC VS NYLON
Density
Impact
Flexural
Modulus
(Dry)
Tensile
Strength
(Dry)
HDT
Equilibrium
Moisture
— PKE-GF PA12-GF PA612-GF
5
4
3
2
1
0
Impact
Shrink
Flexural
Modulus
(Dry)
Chemical
Resistance
Flexural
Modulus
(Cond.)
CO2
Emission
Factor
— Trilliant HC — PA6-GF — PA66-GF
HDT
Wear
Density
5
4
3
2
1
0
Equilibrium
Moisture
1: Poor 3: Good 5: Excellent
1.844.4AVIENT
www.avient.com
Copyright © 2023, Avient Corporation.