https://www.avient.com/sites/default/files/2021-10/maxxam-fr-category-cable-case-study.pdf
MAJOR W&C
PRODUCER
C A T E G O R Y C A B L E
• Flame retardance
• Replace fluorinated ethylene propylene (FEP)
• High tensile strength and high elongation at break
• Low dielectric constant (Dk) of 2.7-2.9 for data signal
integrity
• Satisfied stringent UL 444 requirements with
an FEP alternative to achieve cost savings
• Mitigated regulatory concerns with
comprehensive technical support during
testing and commercialization
• Met required melt strength parameters for
efficient profile extrusion
Maxxam™ FR Flame Retardant Polyolefin
Formulations
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-strengthmembers.pdf
K58220T N/A Kevlar®
2480 LBs
(1125 KGs)
230 FT/LB
(154 M/KG)
Flat 2.81 mm N/A
Strength member in
cable application
Product ID
Polymer Jacket
Base Fiber
Break
Yield Geometry
Nominal
Diameter
Description
13.75mm
K/Hytrel
Hytrel Jacket Kevlar®
29000 LBs
(13154 KGs)
138 KGs/KM Round 13.75mm
Kevlar rope w/ Hytrel
12.5mm K/TPU TPU jacket Kevlar®
24000 LBs
(10885 KGs)
115 KGs/KM Round 12.5mm
Kevlar rope w/ Hytrel
7.87mm
K/MDPE
MDPE Jacket Kevlar®
24000 LBs
(10885 KGs)
50 KGs/KM Round 7.87mm
Kevlar w/ MDPE
.58mm C/PU TPU jacket Carbon
74 LBs
(33.6 KGs)
N/A Round/ Flat .58mm
Carbon w/ TPU
4.50mm
K/HDPE
HDPE jacket Kevlar®
2000 LBs
(907 KGs)
16 KGs/KM Round 4.06 mm
Kevlar w/ HDPE
POPULAR JACKETED STRENGTH MEMBERS
This data is provided for informational purposes only, and does not constitute a specification.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2024-12/PKE grades for Powersports Application Bulletin.pdf
Gasoline - 30% glass-filled (GF) grade, dry as molded (DAM), room temperature
Testing methodology is an adaptation from ASTM D543
• Reapply freshly soaked gauze pad every 24 hours to prevent from drying out
• Repeat for a total of 72 hours
• Tensile properties recorded
*Chemical resistance data for DEET, motor oil, glass cleaner, and sunscreen available upon request
KEY CHARACTERISTICS
Figure 1
Figure 2
3.34
3.84
3.63
1.96
2.21
0.99
3.43
3.86 3.93
1.76
3.49
2.01
3.26
3.66 3.74
1.45
1.06 0.989
2.98
3.99
3.41
1.41
1.07
0.88
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
30% LGF PKE 30% LGF PA6 30% LGF PA66 30% SGF PKE 30% SGF PA6 30% SGF PA66
Ft
-lb
/in
Notched Izod Impact
ASTM D256
23C DAM 23C Conditioned -40C DAM -40C Conditioned
1.47
1.37 1.37
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
Glass-Filled PKE Glass-Filled PA6 Glass-Filled PA66
g/
cm
3
Density of Polyketone vs Nylon
ASTM D792
LESS MOISTURE ABSORPTION THAN NYLON
30% Short Glass Fiber (SGF) Comparison
Moisture uptake, environmental chamber 62% RH, 70°C
SIMILAR DENSITY TO NYLON
ASTM D792
COMPARABLE AND CONSISTENT IMPACT PERFORMANCE*
Notched Izod Impact (ASTM D256) of LGF and SGF for DAM and
Conditioned Materials
*3,000 hr weathering data available upon request
KEY CHARACTERISTICS
1.844.4AVIENT
www.avient.com
Copyright © 2024, Avient Corporation.
https://www.avient.com/sites/default/files/2024-10/Avient_CodeConduct_2024_INDO2.pdf
Ini termasuk cara Anda mengumpulkan,
menggunakan, menyimpan, membagikan, dan melindungi atau
menghapus atau membuang data pribadi.
Perinciannya tercakup dalam Kebijakan Privasi dan Perlindungan
Data Global yang tersedia di The Loop, dalam bagian Personalia &
Departemen, Kebijakan Etika & Perusahaan.
Anda harus
membiasakan diri dan mematuhi kebijakan, prosedur, dan protokol
perusahaan tentang keamanan, manajemen informasi, dan keamanan
siber, termasuk, tetapi tidak terbatas pada kebijakan, prosedur, dan
protokol perusahaan yang tercantum dalam Kebijakan Penggunaan
Sistem Informasi Avient, Kebijakan Privasi dan Perlindungan Data
Global, serta Kebijakan Tanggap Insiden Siber dan Data.
https://www.avient.com/sites/default/files/2022-10/Cesa WithStand Patient Mobility Case Study %281%29.pdf
Avient has compiled extensive data
that enabled the OEM to shave weeks off the product
development timeline and save nearly $50,000 in
potential antimicrobial product protection testing fees.
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-twisting.pdf
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2021-05/renol-ul94-compliant-masterbatches-brochure.pdf
UL94 COMPLIANT
MASTERBATCHES
DESIGN &
SAFETY
High-impact colors and cutting-edge design are hugely important
to the success of today’s sleek, modern electrical and electronic
products.
At the same time, manufacturers also need to consider
product safety and regulatory compliance.
The comprehensive solutions
provided by Avient meet customer requirements and improve the
safety for consumers of electrical and electronic devices.
https://www.avient.com/sites/default/files/2023-01/ECCOH XL Cross-Linkable Solutions _8001_ Product Bulletin.pdf
Highly flame retardant—helps to prevent
a fire, or limit the damage if one starts
• Non-halogenated—in the case of a fire,
there are no acid gas emissions which can
damage equipment and buildings
• Low smoke—in the event of fire, people can
locate escape routes, and fire fighters can
quickly find the source of the fire
• Low toxicity—in the event of a fire, people
are not overcome by toxic fumes
• Low dripping—no flaming droplets which
can further propagate the fire or cause injury
• Low emission of corrosive gases when
burned—avoids potential damage to
electrical components and equipment, and
improves human safety
MARKETS AND APPLICATIONS
The ECCOH XL 8001 is a flame retardant material
for thermoset cable insulation.
https://www.avient.com/sites/default/files/2020-10/tpes-for-automotive-hvac-product-bulletin.pdf
GLS automotive TPEs are designed to improve driver and passenger safety and comfort.
https://www.avient.com/sites/default/files/2020-10/wire-cable-1-pager.pdf
APPLICATIONS: Power cables, Ethernet category cables, industrial cables, solar installation cables, coaxial cables,
fiber optics, hybrid cables
SYNCURE™
Cross-Linked Polyethylene for Power Cable Insulation
• Resistant to heat, oil, creep and abrasion
• Fast extrusion speeds
• UL 44 & UL 4703 flame performance
• UL/CSA bulletins
MAXXAM™ FR W&C
Flame Retardant Polypropylene for Category Cable
Insulation and Cross-Webs
• Alternative to FEP
• Low dielectric
• Thin wall extrusion capabilities
• UL 444 & plenum yellow card flame performance
FIRECON™
Flame Retardant Chlorinated Polyethylene
for Industrial Cable Jackets
• Resistance to harsh environments
• Low temperature properties
• UV resistance
• UL 44 flame performance
ECCOH™ LSFOH
Low Smoke and Fume, Non-Halogen for Insulation
and Jackets
• Low smoke and toxicity
• Improved fire safety
• Resistance to chemicals
• UL44 and CPR flame performance
ADDITIONAL SOLUTIONS
MAXXAM™ SY
Foamed Polypropylene for Coaxial Cable Insulation
SYNPRENE™
Flame Retardant Thermoplastic Elastomers
POLYMIX™
Customer Proprietary Formulations
For more information, please visit avient.com
or call +1.844.4AVIENT (+1.844.428.4368).